-40%
Sencore Beam Rite CR7000 CRT Analyzer & Restorer
$ 422.4
- Description
- Size Guide
Description
Sencore Beam Rite CR7000 CRT Analyzer & Restorer. Condition is "Used". Shipped with USPS Priority Mail. Has setup book.The CR7000 quickly and accurately tests and restores most CRTs. The CR7000 tests analyze the electron gun and provide you with accurate information about the gun's condition. The CR7000 provides six types of cathode restoration plus a G1 shorts removal feature to bring extra life back to most weak or shorted electron guns.
Features:
Tests For All CRTs, Including: Computer Monitors, Video Displays, Televisions, Projection TVs, Scopes, and special application CRTs The CR7000 now has full dynamic range to test all CRTs - old and new
Newly Designed Sockets Allow Easy Connection To Hard To Reach CRTs - New socket design allows the user to test projection TVs and computer monitors faster and easier
The Most Accurate And Thorough Tests Of Any CRT Tester - Exclusive sliding "Good/Bad" scale duplicates manufacturer's test for the most accurate test results available - Exclusive "Low Level" and "High Level" tracking tests locate color tracking pr
The Easiest To Use CRT Tester On The Market - Simply connect one of the six supplied adapters to test virtually all new CRTs without setting and resetting cumbersome setup switches - Tests all three guns of color CRTs, with simultaneous display of
The Safest and Most Effective Restoration Techniques Available - Progressive Restoration Guarantees The Safest Possible Restoration. - Six levels of "Progressive Restoration" - Self-limiting shorts removal function - Three times the restoration
Specifications:
G1 Shorts Test :
20 megohm center scale H-K Shorts: 2 megohm center scale
G2 Voltage Test :
Range: 10-400 VDC Video 1, Proj, and Scope CRT types; 15-600 VDC Video 2 CRT type
Bias Voltage Test :
Range: Video & Projection: 20, 36, 52, 68, 84, 100, 116, 132, 148, 164, 184 VDC; Scope: all bias voltages divided by 10
Cutoff & Low Tracking Test :
Tests ratio of G2 voltages needed to produce cutoff current in all 3 guns of a color CRT. Cutoff current measured between K and G1. "Good" indication if the G2 voltages are within 1.25:1
Emission Test :
Measures true beam current reaching G2
Life Test :
Provides approximate indication of cathode reserve current by lowering filament voltage by 25%
Hi Tracking Test :
Automatically compares emission current between highest and lowest guns in "Simultaneous" gun test and indicates Good/Bad result with LED
Filament Voltage :
Range: 0-4; 4-8; 8-16 VDC
Reactive Restore :
Filament voltage; 50% boost Current limit: 1 mA max, Filament voltage; normal Current limit: 40 mA max
Normal Restore :
Filament voltage; normal Current limit: 80 mA max. with 2 automatic cycles
High Restore :
Filament voltage; 50% boost Current limit: 100 mA max. with 3 automatic cycles
Extended Restore :
Filament voltage; 50% boost Current limit: 100 mA max
Remove G1 Shorts :
Capacitive discharge between G1 and K/G2 after 20 second delay for filaments to cool
Rejuv :
Capacitive discharge between G1 and K (400V)
Size :
7 3/4 x 12 1/2 x 8 3/4 inches
Weight :
13 pounds
Power :
150-125 VAC 50/60 Hz (210-230 VAC available)