Medical Oxygen Regulator Oxygen Inhaler Depressor Buoy Type Oxygen Inhaler CE

$ 27.8

Availability: 15 in stock
  • Safety valve: 0.5mpa automatic exhaust
  • Modified Item: No
  • All returns accepted: ReturnsNotAccepted
  • MPN: Does Not Apply
  • Compatible Gases: Oxygen
  • Country/Region of Manufacture: China
  • Custom Bundle: No
  • Brand: Unbranded
  • Outlet thread: M12x1
  • Condition: New
  • Item Type: Oxygen Regulator
  • Flow regulation range: 1-10L /min
  • Output pressure: 0.25mpa
  • Input pressure: <15Mpa

    Description

    Medical Oxygen Regulator Oxygen Inhaler Depressor Buoy Type Oxygen Inhaler CE
    Parameter:
    Product name: buoy · oxygen inhaler
    Input pressure: <15Mpa
    Output pressure: 0.25mpa
    Flow regulation range: 1-10L /min
    Safety valve: 0.5mpa automatic exhaust
    Inlet thread: g5/8 ""
    Outlet thread: M12x1
    Operation method:
    1. Add distilled water to the humidified cup. The water level in the bottle should not be higher than the upper water line, but should not be lower than the lower water line. Never use normal saline instead.
    2. Insert oxygen inhaler terminal should be closed before the flow regulation switch socket, quick plug direction, and adjust the oxygen and oxygen to aim the quick plug socket terminal holes inserted, when they hear "click" sound and see oxygen terminal socket lock set of automatic sliding, quick plug and oxygen terminal socket is connected to lock.
    3. Insert the oxygen tube into the oxygen transmission joint before oxygen supply, and then turn the flow regulation switch counterclockwise to start the origin, so that the float slowly rises (the scale line aligned with the center of the float is the flow reading, unit is l/min), oxygen supply can be adjusted as needed.
    4. In the process of oxygen supply to the inhaler, if the water in the bottle of the inhaler is lower than the lower water line, it shall timely turn off the flow adjustment switch, unscrew the wet bottle body, add distilled water according to the requirements of article 1, and unscrew the bottle body of the inhaler to continue the oxygen supply.
    5. When the inhaler ceases to be used, the air source of the inhaler shall be closed; If it is necessary to remove it, hold the inhaler by hand and remove it (the unlocking method of different oxygen supply terminal sockets shall be explained by the engineering installation unit), and then clean and disinfect the water in the dropped bottle and store it in a non-corrosive and well-ventilated room).